Product Description
Inquiry
Related Products
COSO PEC2005C metal separator is metal contamination detection and separation equipment with high-sensitivity detection and anti-interference ability.
Function
Detects metal contaminants such as ferrous, copper, aluminum, stainless steel in granules and powers.
Detects metal contaminants such as ferrous, copper, aluminum, stainless steel in granules and powers.
Features
1. With unique sensor manufacturing technology and digital signal processing technology and algorithm, offers high-precision detection and stable performance.
2. Equipped with automatic balance adjustment and automatic drift compensation without manual adjustment.
3. Product self-learning and memory functions can automatically compensate product effect, reducing false alarms and rejections, enhancing detection efficiency.
4. Automatically stores and exports up to 1,500 operation & detection logs, and alarm records for easy counting, querying, and tracing of data.
5. Supports multi-language user interface, allows for tiered access control.
6. Product-contact parts are made of food-grade materials, complying with ISO, HACCP, GMP, FDA, SC, and other certifications for the food and pharmaceutical industries.
7. Offers multiple inlet diameter options, meeting different throughput requirements for material handling.
Specification
| Model | PEC2005C-30 | PEC2005C-40 | PEC2005C-50 | PEC2005C-60 | PEC2005C-70 | PEC2005C-100 | PEC2005C-120 | PEC2005C-150 | PEC2005C-200 | |
| Inner Pipe Diameter (Фmm) | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 130 | 180 | |
| Sensitivity | Fe(Фmm) | 0.20 | 0.23 | 0.25 | 0.33 | 0.40 | 0.45 | 0.50 | 0.65 | 0.75 |
| SUS(Фmm) | 0.26 | 0.28 | 0.30 | 0.42 | 0.53 | 0.80 | 0.90 | 1.08 | 1.28 | |
| Max.Throughput (L/h) | 200 | 450 | 1,500 | 2,300 | 3,400 | 6,300 | 11,000 | 19,000 | 36,000 | |
| Air Compression | 0.3–0.5 MPa | |||||||||
| Defectives Eliminated Time | 0.05–60 s | |||||||||
| Material Temperature | ≤60℃ | |||||||||
Note: The listed sensitivity values are obtained with test blocks passing through the detection pipe (under no-load conditions). Actual sensitivity may vary depending on product characteristics or operating environment; always refer to the actual sensitivity. Technology upgrades may improve sensitivity, consult sales for the latest data. The listed models are selected standard configurations; other configurations are available; contact sales for details.